The approved grade schedule
Which grades are permitted for each circuit, and at which metal temperatures. The schedule is code-driven, not catalogue-driven.
Boiler
Boiler tube selection is a code decision before it is a purchasing decision. Each circuit in a unit operates at its own metal temperature and in its own environment, and the approved grade schedule for that circuit governs what can be supplied.
Boiler circuits
A boiler is not one temperature. What changes between these circuits is the operating envelope, and that envelope is what the grade schedule answers to.
| Circuit | What the duty involves | Before you enquire |
|---|---|---|
| Waterwall and furnace-wall tubes | Exposed to radiant heat and to the furnace atmosphere, so both the temperature and the environment act on the tube. | State the design code, the grade schedule and the required surface condition. |
| Superheater and reheater tubes | The highest metal temperatures in the unit, and the duty where grade selection is most tightly specified. | Provide the code-approved grade and the outlet temperature basis. |
| Economiser tubes | Lower-temperature heat recovery, where the feedwater condition affects the corrosion requirement. | State the feedwater condition and the applicable grade. |
| Heat-exchanger and condenser tubes | Tube-to-tubesheet joints and the cooling medium both influence the material requirement. | State the medium, the joint method and the required grade. |
| Steam and feedwater connection tubing | Small-bore runs where the termination and the pressure basis govern. | Provide the fitting or termination detail and the design basis. |
| Replacement and outage programmes | The replacement tube has to match the unit as built, including any permitted change already approved. | Supply the as-built schedule and the approval history for the unit. |
The design code
These belong to the equipment design and the responsible engineering authority. A tube supplier can quote against them; it cannot set or waive them.
Which grades are permitted for each circuit, and at which metal temperatures. The schedule is code-driven, not catalogue-driven.
Allowable stress at temperature follows from the code and the grade — it is not a tube property that can be read off a mill certificate.
The condition the tube must be in at delivery, and any treatment after forming or welding.
Which tests are required, at which stage, and who witnesses or certifies them.
Approval warning. No grade, temperature limit, stress value or test requirement is published on this page, and no tube or circuit is approved for boiler service here. Those determinations rest with the design code and the responsible engineering authority for the unit.
Supply decisions
Once the code-approved schedule is settled, six supply decisions remain — and each one is a field on the enquiry.
The Alloy Steel Tube page covers the material family across mechanical and thermal duties, and provides the specification builder and RFQ handoff.
Related pages
The circuit and the code come first. The standard, grade and treatment follow them.
The material family, separated by mechanical and thermal duty, with the specification builder.
The boiler and heat-exchanger tube specification and its wide grade range.
Keeping each circuit, grade and heat separate through quotation and receipt.